Geothermal Injection Capacity Expansion
Summary
SCH Number
2026010762
Public Agency
California Energy Commission
Document Title
Geothermal Injection Capacity Expansion
Document Type
NOE - Notice of Exemption
Received
Posted
1/23/2026
Document Description
This project will improve and expand the existing geothermal heating system utilized by the Modoc Medical Center in the City of Alturas. The strategy is to convert an existing, unused geothermal production well into an injection well. The additional injection well will provide the necessary injection capacity to serve the expanded Modoc Medical Center facilities and future users. The project will provide economic benefits to Alturas and the surrounding Modoc County communities by lowering heating costs, providing services to medical personnel, and supporting local businesses.
Contact Information
Name
Erica Loza
Agency Name
California Energy Commission
Job Title
Electric Generation System Specialist I
Contact Types
Lead/Public Agency
Phone
Email
Location
Coordinates
Cities
Alturas
Counties
Modoc
Regions
Northern California
Zip
96101
Other Location Info
900 North Main Street
Notice of Exemption
Exempt Status
Categorical Exemption
Type, Section or Code
Cal. Code Regs., tit 14 § 15301, Cal. Code Regs., tit 14 §15302
Reasons for Exemption
Cal. Code Regs., tit. 14 § 15301 provides that the operation, repair, maintenance, permitting, leasing, licensing, or minor alteration of existing structures, facilities, mechanical equipment, or topographical features involving negligible or no expansion of existing or former use are categorically exempt from the provisions of CEQA. This project will involve minor alteration of existing structures involving negligible or no expansion of existing or former use. This project will increase injection capacity for a geothermal heating system currently serving the Modoc Medical Center, Modoc Schools, and swimming pool by converting an existing, unused geothermal production well into an injection well. Existing pipelines will be accessed, and new pipelines will be installed in the parking lot and roadways of the High School. This conversion only entails modest alterations to the unused production well and geothermal heating system and makes no significant changes to roads, the well pad, or surrounding vegetation, nor does it entail complicated modifications, such as major reconstruction of the injection well. The well is currently unused but was formerly a geothermal production well connected to a geothermal aquifer. The production well will be converted to an injection well to inject geothermal water after heat extraction into the same geothermal aquifer. The injection well will be cleaned and opened to its original drilled depth. The integrity of the injection well casing will be tested to ensure injected geothermal water is not allowed to escape, meaning it will be geologically confined within the injection well until it reaches the appropriate depth to remain in the aquifer. Although unlikely, there is a possibility that the injection well may be deepened slightly to increase injection capacity. All trenching will be conducted in previously disturbed areas, such as the parking lot and roadways of the High School. Project activities will be performed in accordance with all applicable rules and regulations, including obtaining a permit for the well modifications from the California Geologic Energy Management Division.
Cal. Code Regs., tit. 14 § 15302 provides that the replacement or reconstruction of existing structures where the new structure will be located on the same site as the structure replaced and will have substantially the same purpose and capacity as the structure replaced are categorically exempt from the provisions of CEQA. This project will involve the replacement or reconstruction of existing structures, where the new structure will be located on the same site as the replaced structure and will have substantially the same purpose and capacity as the structure replaced. This project is comparable to the replacement or reconstruction of existing utility systems involving negligible expansion of capacity, as described in Cal. Code Regs., tit. 14, § 15302 (c). This project will convert an existing unused geothermal production well into an injection well. The former production well, converted to a new injection well, will serve the same purpose- to provide geothermal heating to Modoc Medical Center facilities. Although the well is currently unused, it was formerly a geothermal production well with production capacity for heating. This project will convert the production well to an injection well in order to increase capacity for Modoc Medical Center’s geothermal heating system. The project will not impact an environmental resource of hazardous or critical concern where designated, precisely mapped, and officially adopted pursuant to law by federal, state, or local agencies; does not involve any cumulative impacts of successive projects of the same type in the same place that might be considered significant; does not involve unusual circumstances that might have a significant effect on the environment; will not result in damage to scenic resources within a highway officially designated as a state scenic highway; the project site is not included on any list compiled pursuant to Government Code section 65962.5; and the project will not cause a substantial adverse change in the significance of a historical resource. None of the exceptions to categorical exemptions listed in CEQA Guidelines section 15300.2 apply to this project, and this project will not have a significant effect on the environment. Therefore, the project will not have a significant effect on the environment and is categorically exempt under CEQA Guidelines sections 15301 and 15302.
County Clerk
Modoc
Attachments
Notice of Exemption
Disclaimer: The Governor’s Office of Land Use and Climate Innovation (LCI) accepts no responsibility for the content or accessibility of these documents. To obtain an attachment in a different format, please contact the lead agency at the contact information listed above. For more information, please visit LCI’s Accessibility Site.