Guynn Bridge Replacement Project
3 Documents in Project
Summary
SCH Number
2025030683
Lead Agency
City of Chico
Document Title
Guynn Bridge Replacement Project
Document Type
NOD - Notice of Determination
Received
Posted
8/19/2025
Document Description
The project includes the demolition and replacement of the existing structurally deficient single-lane Guynn Bridge. The new structure will accommodate two 11-foot travel lanes, five-foot shoulders, and a six-foot sidewalk on the east side. The new bridge is anticipated to be an approximately 90-foot-long single-span, precast, prestressed concrete box beam structure. Construction of the bridge will involve excavation for and construction of concrete abutments on deep foundations. Temporary work within Lindo Channel includes installation of scour countermeasures at the support locations, including approximately 80 cubic yards of rock slope protection.
Contact Information
Name
Lynn Coster
Agency Name
Central Valley Regional Water Quality Control Board
Job Title
Senior Environmental Scientist
Contact Types
Responsible Agency
Phone
Name
Tracy Bettencourt
Agency Name
City of Chico Public Works
Job Title
Senior Planner
Contact Types
Lead/Public Agency / Project Applicant
Address
Phone
Location
Coordinates
Cities
Chico
Counties
Butte
Regions
Northern California
Parcel #
043-630-014, 043-630-074, 043-630-076, 042-600-012
Township
22 N
Range
1 E
Section
34
Base
MDB&M
Notice of Determination
Approving Agency
Central Valley Regional Water Quality Control Board
Approving Agency Role
Responsible Agency
Approved On
County Clerk
Butte
Final Environmental Document Available at
This is to certify that the Mitigated Negative Declaration is available for public review at the City's website: https://chico.ca.us/Departments/Engineering/Capital-Projects/Guynn-Avenue-Bridge-Replacement-Project/index.html.
Determinations
(1) The project will have a significant impact on the environment
No
(2a) An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA
No
(2b) A Mitigated or a Negative Declaration was prepared for this project pursuant to the provisions of CEQA
Yes
(2c) An other document type was prepared for this project pursuant to the provisions of CEQA
No
(3) Mitigated measures were made a condition of the approval of the project
Yes
(4) A mitigation reporting or monitoring plan was adopted for this project
Yes
(5) A Statement of Overriding Considerations was adopted for this project
No
(6) Findings were made pursuant to the provisions of CEQA
Yes
Attachments
Notice of Determination
Disclaimer: The Governor’s Office of Land Use and Climate Innovation (LCI) accepts no responsibility for the content or accessibility of these documents. To obtain an attachment in a different format, please contact the lead agency at the contact information listed above. For more information, please visit LCI’s Accessibility Site.