Well Q2 Perchlorate Removal Facility
Summary
                SCH Number
            
            
                2023070536
            
        
                    Public Agency
            
            
                State Water Resources Control Board
                
            
        
                Document Title
            
            Well Q2 Perchlorate Removal Facility
        
                Document Type
            
            
                NOE - Notice of Exemption
            
        
                Received
            
            
                    Posted
                
                
                    7/25/2023
                
            
                Document Description
            
            The Santa Clarita Valley Water Agency - Valencia Division (hereinafter Valencia Division) proposed Project includes Well Q2 Ion Exchange (IX) Treatment Facility and the Disinfection Facility at the location described above. The Valencia Division will utilize IX treatment to remove perchlorate and per- and polyfluoroalkyl substances (PFAS) from the raw water of Well Q2, which has a capacity of 1,320 gpm. The effluent from the IX vessels will then receive chloramination treatment at the Saugus Perchlorate Treatment Facility (SPTF). The Well Q2 IX Treatment Facility includes two bag filters and one treatment train (two IX vessels total, operated in lead and lag configuration). The Disinfection Facility includes existing sodium hypochlorite storage and liquid ammonium sulfate storage at the SPTF, and additional chemical feed systems installed for both sodium hypochlorite and liquid ammonium sulfate. Both treatment facilities are equipped the associated electrical equipment, Supervisory Control and Data Acquisition (SCADA) system, and water quality measuring equipment.
        Contact Information
                        Name
                    
                    
                        Naira Ghukasyan
                    
                
                        Agency Name
                    
                    
                        State Water Resources Control Board
                    
                
                            Job Title
                        
                        
                            Environmental Scientist
                        
                    
                        Contact Types
                    
                    
                        Responsible Agency
                    
                
                            Phone
                        
                        
                    Location
                    Cities
                
                Santa Clarita
            
                    Counties
                
                Los Angeles
            
                    Regions
                
                Southern California
            
                    Cross Streets
                
                
                    26477 Bouquet Canyon Rd
                
            Notice of Exemption
                            Exempt Status
                        
                        
                            Categorical Exemption
                        
                    
                            Type, Section or Code
                        
                        
                            Class 1 Existing Facilities, and Class 3 New Construction or Conversion of Small Structures. 
                        
                    
                            Reasons for Exemption
                        
                        
                            he project qualifies for an exemption under Class 1 Existing Facilities because it is a minor alteration of an existing public facility and it concerns proposed new mechanical equipment involving negligible or no expansion of use. The project also qualifies for an exemption under Class 3 New Construction or Conversion of Small Structures because the project construction is limited to construction within SCVWA's existing facility property. None of the exceptions listed in section 15300.2 of the CEQA Guidelines would apply to the proposed Project.
                        
                    Attachments
                        Notice of Exemption
                    
                    
                Disclaimer: The Governor’s Office of Land Use and Climate Innovation (LCI) accepts no responsibility for the content or accessibility of these documents. To obtain an attachment in a different format, please contact the lead agency at the contact information listed above. For more information, please visit LCI’s Accessibility Site.